| PV-Anlage --- Ilbesheim_RWS --- 153,250 kWp --- Stand 26.04.26-18:40:00 | ||
|---|---|---|
| aktueller Tag mit Einzelwerten (AC,DC) aller Wechselrichter | ||
| PV-Monitoring --- (c) pvmoni --- V1.75 2025-08-19 days_htm.php | ||
| Erstellt am 26.04.26-20:57 | - Files='days.js + base_vars.js + min_cur.js' - | |
| #30 --- PV-Ilbesheim_RWS --- '26-04-26/18:40:00' --- Übersicht Datenlogger SolarLog | |||||
| PV-Anlage | Datum | SolarLog | SerienNr | Firmware | Wirkungsgrad AC / DC |
| Ilbesheim_RWS | 26-04-26/18:40:00 | 500 | 15709837 | 2.0.4 Build 24 - 16.04.2010 | 93 ... 96 ... 98 % |
| Vergütung Cent/kWh | Sum-AC [Watt] | Sum-DC [Watt] | DC-A [Watt] | DC-B [Watt] | DC-C [Watt] |
| 30.00 | 577 | 616 | 616 | - | - |
| PV-Ilbesheim_RWS --- '26-04-26/18:40:00' --- aktuelle Wechselrichter-Werte ---Datum---'26_04_26/20:57:17'--- | ||||||||||||
| #1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | |||
| WR | DC-Summe | AC | Wirkungsgrad | AC-Ertrag | WR | Ertrag | Riso | Status | Fehler | |||
| Nr | Watt (Wh/Wp) | Watt (Wh/Wp) | AC / DC | Wh | Wp | kWh/kWp | kOhm | #22 | #11 | |||
| WR-01 | 81 ( 0,00 ) | 68 ( 0,00 ) | 83.95 % | 102.700 | 22.480 | 4,57 | - | 2=2=Activation | - | |||
| WR-02 | 5 ( 0,00 ) | 69 ( 0,00 ) | 1380.00 % | 92.500 | 23.020 | 4,02 | - | 1=1=Switched off | - | |||
| WR-03 | 217 ( 0,01 ) | 191 ( 0,01 ) | 88.02 % | 0 | 22.480 | 0,00 | - | 4=4=Run | - | |||
| WR-04 | 75 ( 0,00 ) | 65 ( 0,00 ) | 86.67 % | 104.500 | 22.480 | 4,65 | - | 1=1=Switched off | - | |||
| WR-05 | 65 ( 0,00 ) | 63 ( 0,00 ) | 96.92 % | 67.300 | 17.830 | 3,77 | - | 1=1=Switched off | - | |||
| WR-06 | 95 ( 0,00 ) | 55 ( 0,00 ) | 57.89 % | 106.500 | 22.480 | 4,74 | - | 2=2=Activation | - | |||
| WR-07 | 78 ( 0,00 ) | 66 ( 0,00 ) | 84.62 % | 108.800 | 22.480 | 4,84 | - | 5=5=Ramp back to zero | - | |||
| SUMME | 616 ( 0,00 ) | 577 ( 0,00 ) | 93.67 % | 582.300 | 153.250 | 3,80 | Riso | - | - | |||
| PV-Ilbesheim_RWS --- '26-04-26/18:40:00' --- WR_Beschreibung / SN | ||||||
| #1 | #2 | #3 | #4 | #5 | #6 | #7 |
| WR | WR | SerienNr=SN | WR | Eingang-A | Eingang-B | Summe |
| Nr | Typ | Nummer | Name | Wp | Wp | Wp |
| WR-01 | Refusol 20kw | 010021825 | WR-1___22,48kWp-14,67% | 22.480 | - | 22.480 Wp |
| WR-02 | Refusol 20kw | 010021829 | WR-2___23,02kWp-15,02% | 23.020 | - | 23.020 Wp |
| WR-03 | Refusol 20kw | 010013011 | WR-3___22,48kWp-14,67% | 22.480 | - | 22.480 Wp |
| WR-04 | Refusol 20kw | 010021828 | WR-4___22,48kWp-14,67% | 22.480 | - | 22.480 Wp |
| WR-05 | Refusol 17kw | 010018798 | WR-5___17,83kWp-11,63% | 17.830 | - | 17.830 Wp |
| WR-06 | Refusol 20kw | 010021818 | WR-6___22,48kWp-14,67% | 22.480 | - | 22.480 Wp |
| WR-07 | Refusol 20kw | 080077645 | WR-7___22,48kWp-14,67% | 22.480 | - | 22.480 Wp |
| SUMME | ||||||
| Sum-Wp | 153.250 Wp | - | 153.250 Wp | |||
| --- Tabelle für 'REFUsol'-Wechselrichter |
| SolarLog-Status-Tabelle ( #22 Werte) |
| 0='0=Initialization' |
| 1='1=Switched off' |
| 2='2=Activation' |
| 3='3=Ready' |
| 4='4=Run' |
| 5='5=Ramp back to zero' |
| 6='6=Break' |
| 7='7=Fault' |
| 8='8=Testing' |
| 9='9=NoCountrySet' |
| 10='10=Update' |
| 11='11=...' |
| 12='12=...' |
| 13='13=...' |
| 14='14=...' |
| 15='15=...' |
| 16='16=ShutDown' |
| 17='17=...' |
| 18='18=...' |
| 19='19=...' |
| 20='20=Generated' |
| 21='21=NoData' |
| --- Tabelle für 'REFUsol'-Wechselrichter |
| SolarLog-Fehler-Tabelle ( #11 Werte) |
| 0='0=---' |
| 1='1=F1' |
| 2='2=F2' |
| 3='3=F3' |
| 4='4=F4' |
| 5='5=F5' |
| 6='6=F6' |
| 7='6=F7' |
| 8='8=F8' |
| 9='9=F9' |
| 10='10=F10' |